-50% discount* If you buy the same UNE standard in different languages. * Discount on the lower pvp.

CEN/TS 16817-1:2015

Ambient air - Monitoring the effects of genetically modified organisms (GMO) - Pollen monitoring - Part 1: Technical pollen sampling using pollen mass filter (PMF) and Sigma-2-sampler

Edition date: 2025-03-06
In Force
Available languages: English, French, German
Summary: Die vorliegende Technische Spezifikation beschreibt ein Verfahren zur Verwendung der Passivsammler Sigma-2 und PMF zur Sammlung von luftgetragenen Pollen. Beide Sammler sind auf die Sammlung grober Aerosolpartikel ausgelegt. Gesammelte Proben werden zur Analyse des Polleneintrags hinsichtlich Pollenart, Pollenmenge und dem Eintrag von transgenen Pollen verwendet. Der Sigma-2-Sammler dient hierbei der standardisierten Probenahme zur direkten mikroskopischen Pollenanalyse und der quantitativen Bestimmung des in der Luft vor Ort vorhandenen Polleneintrags. Durch den PMF können ausreichende Pollenmengen für zusätzliche molekularbiologische Diagnostiken zum GVO-Nachweis erhalten werden. Wesentliche Grundlagen zur Durchführung des GVO-Monitorings werden in Richtlinie VDI 4330 Blatt 1 [4] vermittelt, basierend auf einer integrierten Beurteilung von zeitlichen und räumlichen Variationen des GVO-Anbaus (GVO-Quellen), der Umweltexposition sowie biologischen/ökologischen Wirkungen. Im Idealfall sollte die Pollensammlung mit technischen Sammlern für das GVO-Monitoring in Kombination mit der biologischen Pollensammlung durch Bienen vorgenommen werden (CEN/TS 16817-2). Der Einsatz von technischen Passivsammlern und die Verwendung von Honigbienenvölkern als aktive biologische Sammler ergänzen sich beim Monitoring der Exposition zu GVO-Pollen in vielfältiger Weise. Während die technischen Sammler repräsentative Ergebnisse zum Polleneintrag am Standort liefern, werden bei der biologischen Sammlung durch die Honigbienen die Pollen der in einem Gebiet vorhandenen blühenden Pflanzen entsprechend der Sammelaktivität gesammelt. Hierbei wird die GVO-Exposition gegenüber umherstreifenden Insekten dargestellt. Die Kombination beider Sammelverfahren repräsentiert die beiden hauptsächlichen Grundsätze der Exposition. Darüber hinaus kann ein breiteres Spektrum an Pollenspezies erfasst werden. Der Messplan richtet sich nach der vorgesehenen Messaufgabe. Siehe 6.2 für Beispiele.

This Technical Specification describes a procedure for the use of the passive samplers Sigma-2 and PMF to sample airborne pollen. Both are designed to sample coarse aerosol particles. Collected samples are used to analyze pollen input with regard to pollen type and amount, and input of transgenic pollen. The Sigma-2 passive sampler here provides a standardized sampling method for direct microscopic pollen analysis and quantifying the aerial pollen input at the site. The PMF yields sufficient amounts of pollen to additionally carry out molecular-biological diagnostics for detection of GMO. Essential background information on performing GMO monitoring is given in Guideline VDI 4330 Part 1 [4], which is based on an integrated assessment of temporal and spatial variation of GMO cultivation (sources of GMO), the exposure in the environment and biological/ecological effects. Ideally, the pollen sampling using technical samplers for GMO monitoring should be undertaken in combination with the biological collection of pollen by bees (FprCEN/TS 16817-2). The application of technical passive samplers and the use of honey bee colonies as active biological collectors complement each other in a manifold way when monitoring the exposure to GMO pollen. Technical samplers provide results regarding the pollen input at the sampling site in a representative way, whereas with biological sampling by honey bee colonies, pollen from flowering plants in the area is collected according to the bees' collection activity. Thus, this method represents GMO exposure to roaming insects. By combining the two sampling methods these two main principles of exposure are represented. Furthermore, a broad range of pollen species is covered. The sample design depends on the intended measuring objective. Some examples are given in 6.2.

La présente Spécification technique décrit un mode opératoire relatif à l’utilisation des échantillonneurs passifs Sigma 2 et FMP pour échantillonner le pollen en suspension dans l’air. Tous deux sont conçus pour échantillonner les grosses particules d’aérosols. Les échantillons prélevés sont utilisés pour analyser l'apport de pollen en termes de type et de quantité de pollen, ainsi que l’apport de pollen transgénique. L’échantillonneur passif Sigma-2 offre ici une méthode d’échantillonnage standardisée pour l’analyse microscopique directe du pollen et la quantification de la dispersion aérienne du pollen sur le site. Le FMP permet d’obtenir des quantités suffisantes de pollen pour effectuer en plus des diagnostics par biologie moléculaire pour la détection des OGM. Des informations générales essentielles sur la surveillance des OGM sont données dans la ligne directrice VDI 4330 Part 1 [4], qui repose sur une évaluation intégrée de la variation spatio-temporelle de la culture d’OGM (sources d’OGM), de l’exposition dans l’environnement et des effets biologiques/écologiques. Dans l’idéal, il convient d’effectuer l’échantillonnage de pollen à l’aide d’échantillonneurs techniques pour la surveillance des OGM en association avec la récolte biologique de pollen par les abeilles (FprCEN/TS 16817­2). L’application d’échantillonneurs techniques passifs et l’utilisation de colonies d’abeilles mellifiques comme échantillonneurs biologiques actifs se complètent à plusieurs niveaux lors de la surveillance de l’exposition au pollen génétiquement modifié. Les échantillonneurs techniques fournissent des résultats représentatifs concernant l’apport de pollen sur le site d’échantillonnage, alors qu’avec les échantillonneurs biologiques tels que les colonies d’abeilles mellifiques, le pollen des plantes à fleurs de la zone est récolté en fonction de l’activité de récolte des abeilles. Cette méthode représente ainsi l’exposition des OGM aux insectes itinérants. En combinant les deux méthodes d’échantillonnage, ces deux principes majeurs d’exposition sont représentés. En outre, une vaste gamme d’espèces de pollen est couverte. Le plan d’échantillonnage dépend de l’objectif de mesurage prévu. Des exemples sont donnés en 6.2.

ICS: 13.020.99-Other standards related to environmental protection, 07.080-Biology. Botany. Zoology
CTN: CEN/TC 264 - 6245

The book in the author's words

Ultricies magna feugiat malesuada sociosqu varius vivamus cubilia parturient, himenaeos vitae vehicula nam placerat netus urna platea, nostra rutrum felis mattis penatibus velit quisque.
Frequently Asked Questions Do you have any questions about our products?
  • Standards UNE, EN, ISO, IEC, BSI, DIN, ASTM, AFNOR, IEEE, SAE
  • In addition, you can request the rules of the rest of the organizations through the e-mail normas@aenor.com
  • Technical books on paper and in electronic format (PDF, epub).

The standards can be purchased in PDF, reading or paper. The reading standards are not download files, they can only be viewed in the client area. The standards ordered on paper and some of the books in the catalogue are printed on demand. 

Check deadlines in normas@aenor.com.

The license of use is for one user and one device, if you want to reproduce the content of the standard, you must request a license that will have an additional cost. Send us your inquiry here 

 

The use of standards and other content protected by intellectual property rights in AI systems is prohibited. If you are interested in such uses, please contact normas@aenor.com. Failure to comply will result in the withdrawal of your Access licence.

The AENOR standards and books that appear in the online store can only be purchased exclusively through the website. AENOR does not have a physical store.

Purchase procedure: by clicking on "Buy" the desired products will go to the shopping cart. If there are display problems, the recommended browser is Chrome.

To formalize the purchase you must access the customer area. If you are not registered as a customer, you must fill in a form with the data along with a password and username. This will create the account.

Once the "Customer data" form has been completed, "Order in progress" will be displayed with all the items loaded in the shopping cart, their prices, taxes established in current legislation and shipping costs if applicable.

The prices of the standards and books that appear in the various sections do not include taxes or shipping costs.

AENOR promotional codes consist of alphanumeric characters and can only be applied to online purchases, received through a specific offer and for a limited time. To apply your promotional code, you just have to enter it in step 2 of 4 of the purchase process on the website and click on "apply", after you have identified yourself and chosen the payment methods. Promo codes are not cumulative.

 

  • Credit or debit card (Visa, Mastercard) and PayPal.
  • Bank transfer. If you opt for this form of payment, you must first send AENOR a copy of the transfer by email to normas@aenor.com
  • The purchase invoice can be downloaded from the customer area, in my previous orders

In the case of clients of companies based abroad, the taxpayer identification number of the corresponding country (for example, in Argentina the CUIT), must be filled in the CIF/NIF - VAT field .

  • Direct download via the website in the Customer Area. In the customer area, which can only be accessed with a password and username, the products purchased will be available for a period of fifteen days from the date of purchase, as long as the payment has been accepted. Files in digital format are protected and in no case editable. Before purchasing them, it is important that the license of use is read and accepted as a prior step to purchase.
  • Shipping by courier. Products purchased on physical media are shipped by courier. The maximum delivery time in Spanish territory, from the acceptance of the order by AENOR, is:
  •  Approximately seven working days for all standards purchased through the store in paper format.
  • Approximately three days for books purchased through the store. Stocks of paper books are limited and their offer on the website does not imply availability within the indicated period. In the event that the requested book is not available, the customer is notified of the delay in receiving the order, which will be approximately seven working days. 

For the rest of the products that are not on the website, check availability and delivery time at normas@aenor.com.

1. For digital products (PDF, Epub), once delivery has been made by direct download via the website in the Customer Area, you will not have the right to exercise your right of withdrawal.

2. For personalised products on paper, once the purchase has been made, you will not have the right to exercise your right of withdrawal.

3.  For all other paper products, you have the right to withdraw from the sale within 14 calendar days from the date of purchase. Remember that for the return it is essential that the product is in perfect condition, sealed by the packaging and preserving its original packaging. The customer will be responsible for pickup and shipping costs.

The order invoice includes shipping costs, so there is no amount to pay to the courier. Shipping costs are calculated based on both the final destination of the order and the number of products ordered. They include transport and packaging costs. Shipping costs are subject to periodic revisions. Outlet books will have free shipping costs only if the shipment is made in the Peninsula.

Destination Up to three standards and/or publications From three standards and/or publications
Peninsula 7,31€ 8,60€
Balearic Islands 18,04€ 23,34€
Canary Islands, Ceuta and Melilla  18,04€ 23,34€
Europe 59,17€ 80,07€
United States and Canada 70,07€ 96,94€
Rest of the world 91,94€ 115,91€
  • Purchases made by residents of the Member States of the European Union will be subject to the payment of VAT (value added tax).
  • ​​
  • In the case of legal persons and natural persons who, acting as entrepreneurs, are domiciled in a Member State of the European Union (except residents in Spain) and have an intra-community NIF/VAT registered in the VIES census, they will be exempt from paying VAT, being an essential condition the sending of this document by email to normas@aenor.com.
  • Purchases made in a private capacity (natural person), regardless of where they have their residence, will be subject to the payment of VAT.
  • Purchases made by entities in non-EU countries will be exempt from paying VAT, as long as they send the corresponding tax residence document by email to normas@aenor.com.
  • The sale operations will be understood to have been carried out at AENOR's registered office: Génova 6, 28004, Madrid – Spain. 

The contract for the purchase of products through this Website shall be governed by Spanish law. Any dispute arising out of or in connection with the use of the Website or such contract shall be subject to the exclusive jurisdiction of the Courts and Tribunals of Madrid.

Notwithstanding the foregoing, if you are entering into this contract as a consumer under the terms of Royal Decree 1/2007, nothing in this clause shall affect the rights that may be granted to you as such under applicable law.