-50% de descuento* Si compras la misma norma UNE en distintos idiomas. * Dto. sobre el pvp inferior. Ver condiciones

ASTM E1191 - 03a(2008)

Standard Guide for Conducting Life-Cycle Toxicity Tests with Saltwater Mysids

¿Abrumado/a por la IA?

Pasa de la teoría a la práctica con el Taller de IA: Fundamentos Prácticos y Maestría. Próximo 4 de Junio

¡RESERVA TU PLAZA AQUÍ!
Equipo trabajando en una oficina moderna
Aviso: Las normas ASTM en lectura se visualizan a través del área de cliente. Los archivos no se pueden descargar
Fecha edición: 2008-02-01
Anulada
Fecha cancelación: 2008-02-01
Idiomas disponibles: Inglés
Keywords: flow-through test; life cycle; mysids; toxicity test; Aqueous environments; Biological data analysis; Brood stock tanks; Chamber; Contact stock solutions; Flow-through test chambers; Fresh water; Life cycle (of aquatic organisms); Marine environments; Metering system; Microbiological water quality; Mysids; Saltwater; Testing methods--environmental analysis; Toxicity/toxicology--water environments
Scope:

1.1 This guide describes procedures for obtaining laboratory data concerning the adverse effects of a test material added to dilution water, but not to food, on certain species of saltwater mysids during continuous exposure from immediately after birth until after the beginning of reproduction using the flow-through technique. These procedures will probably be useful for conducting life-cycle toxicity tests with other species of mysids, although modifications might be necessary.

1.2 Other modifications of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of many other tests. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information on new concepts and procedures for conducting life-cycle toxicity tests with saltwater mysids.

1.3 These procedures are applicable to all chemicals, either individually or in formulations, commercial products, or known mixtures, that can be measured accurately at the necessary concentrations in water. With appropriate modifications, these procedures can be used to conduct tests on temperature, dissolved oxygen, and pH and on such materials as aqueous effluents (see also Guide E 1192), leachates, oils, particulate matter, sediments, and surface waters.

1.4 This guide is arranged as follows:

Section
Referenced Documents2
Terminology3
Summary of Guide4
Significance and Use5
Hazards7
Apparatus6
Facilities6.1
Construction Materials6.2
Metering System6.3
Test Chambers6.4
Cleaning6.5
Acceptability6.6
Dilution Water8
Requirements8.1
Source8.2
Treatment8.3
Characterization8.4
Test Material9
General9.1
Stock Solution9.2
Test Concentration(s)9.3
Test Organisms10
Species10.1
Age10.2
Source10.3
Brood Stock10.4
Food10.5
Handling10.6
Harvesting Young10.7
Quality10.8
Procedure11
Experimental Design11.1
Dissolved Oxygen11.2
Temperature11.3
Beginning the Test11.4
Feeding11.5
Cleaning11.6
Duration of Test11.7
Biological Data11.8
Other Measurements11.9
Analytical Methodology12
Acceptability of Test13
Calculation14
Documentation15
Keywords16
Appendix
X1. Statistical Guidance

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.

ICS: 13.300 - Protección contra materias peligrosas
CTN: E50.47

Anulaciones Normas

Anula a E1191-03A

Otras Relaciones

Es referenciada por E1850-04R19

Es referenciada por E0729-23E01

Es referenciada por E2122-22

Es referenciada por E1022-22

Es referenciada por E1023-23

El libro en palabras del autor

Ultricies magna feugiat malesuada sociosqu varius vivamus cubilia parturient, himenaeos vitae vehicula nam placerat netus urna platea, nostra rutrum felis mattis penatibus velit quisque.

Button
Preguntas frecuentes ¿Tienes alguna duda sobre nuestros productos?

Respuesta 2

Desde la web

Libros y normas