-50% de descuento* Si compras la misma norma UNE en distintos idiomas. * Dto. sobre el pvp inferior. Ver condiciones

ASTM E1768 - 95(2013)

Standard Guide for Ventilatory Behavioral Toxicology Testing of Freshwater Fish (Withdrawn 2022)

¿Abrumado/a por la IA?

Pasa de la teoría a la práctica con el Taller de IA: Fundamentos Prácticos y Maestría. Próximo 4 de Junio

¡RESERVA TU PLAZA AQUÍ!
Equipo trabajando en una oficina moderna
Aviso: Las normas ASTM en lectura se visualizan a través del área de cliente. Los archivos no se pueden descargar
Fecha edición: 2022-01-12
Anulada
Fecha cancelación: 2022-01-12
Idiomas disponibles: Inglés
Scope:

1.1 This guide covers information on methods to measure and interpret ventilatory behavioral responses of freshwater fish to contaminants.

1.2 Ventilatory responses are often some of the first prelethal symptoms exhibited by animals to environmental stressors (1, 2, 3, 4, 5, 6, 7, 8, 9, 10).2 Continued, abnormal ventilatory behavior (that is, rapid or shallow breathing, erratic breathing) can indicate physiological damage that may be irreversible. Such damage could eventually result in decreased survival, growth, or reproduction of the organism, or all of these.

1.3 Ventilatory responses of some fish species can be measured relatively easily and quickly, providing a useful tool for biomonitoring studies of wastewaters, pure chemicals, surface water, and ground water.

1.4 Appropriate studies of ventilatory responses can yield definitive endpoints such as no observable effect concentration (NOEC) or an EC50, often more rapidly than standard toxicity test methods (11, 12).

1.5 The mode of action of test substances and the type of chemical toxicant can be determined by examining ventilatory behavioral responses in conjunction with other physiological responses (8, 9, 10, 11, 12).

1.6 Fish ventilatory behavior can be assessed in real-time using appropriate computer hardware and software (12, 13, 14, 15, 16, 17, 18, 19) . Such systems have proved useful for long-term, on-line monitoring of wastewater effluents, pure chemicals, and surface waters (12, 15, 20, 21, 22, 23, 24, 25) . These systems are usually technically complex and will not be discussed in this guide.

1.7 Given the technological constraints of electrical components, it is currently not feasible to monitor bioelectric signals, such as those elicited in ventilatory behavior, in saline (>2 ppt) or high conductivity (>3000 μmhos/cm) water using the procedures discussed in this guide. Therefore, this guide is restricted to the testing of freshwater matrices.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety precautions, see Section 6.

1.9 This guide is arranged as follows:

 

Section Number

Scope

 1

Referenced Documents

 2

Terminology

 3

Summary of Guide

 4

Significance and Use

 5

Safety Precautions

 6

Responses Measured

 7

Test System

 8

Test Procedure

 9

Data Collection and Analysis

10

Interferences

11

Documentation

12

References

13


ICS: 11.220 - Medicina veterinaria
CTN: E50.47

Anulaciones Normas

Anula a E1768-95R08

Reemplazo Normas

Es reemplazada por No Replacement

El libro en palabras del autor

Ultricies magna feugiat malesuada sociosqu varius vivamus cubilia parturient, himenaeos vitae vehicula nam placerat netus urna platea, nostra rutrum felis mattis penatibus velit quisque.

Button
Preguntas frecuentes ¿Tienes alguna duda sobre nuestros productos?

Respuesta 2

Desde la web

Libros y normas