DIN EN 13828:2025-04
Building valves - Manually operated copper alloy and stainless steel ball valves for potable water supply in buildings - Tests and requirements; German version EN 13828:2025
| Fecha edición: |
2025-04-01
En Vigor
|
|---|---|
| Idiomas disponibles: | Inglés, Alemán |
| Resumen: | This European standard applies primarily to copper alloy ball valves, dimensions DN 8 to DN 100, for potable water supply in buildings up to PN 10 and a distribution temperature of 65 °C. Occasional excursions up to 90 °C are permitted for a period of 1 h maximum. This standard applies also to ball valves in combination with other components in the same body. This standard specifies: - the requirements of the materials and the design of ball valves; - the mechanical, hydraulic and acoustic requirements of ball valves; - the test methods to verify the requirements of ball valves; - the marking requirements of ball valves. Ball valves in combination with other valves should fulfil the same requirements. |
| Keywords: | Alloys|Ball valves|Buildings|Copper|Copper alloys|Definitions|Design|Designations|Dimensions|Drinking water installations|Hand operated|House installations|Marking|Materials|Mechanical properties|Potable water|Properties|Rustless|Service installations in buildings|Shape|Shut-off valves|Specification (approval)|Stainless|Stainless steels|Steels|Stop valves|Taps|Testing|Valves|Water practice|Water supply|Water supply installations |
| ICS: | 23.060.20 - Válvulas de obturador esférico y giratorio |
| CTN: | |
|
Equivalencia Internacional |
Idéntica EN 13828:2025 |
|
Reemplazo Normas |
Reemplaza a DIN EN 13828:2003-12 Reemplaza a DIN EN 13828:2023-02 |