DIN EN 14453:2026-03
Devices to prevent pollution by backflow of potable water - Pipe interrupter with permanent atmospheric vent DN 10 to DN 20 - Family D, type C; German and English version prEN 14453:2026 / Note: Date of issue 2026-02-20*Intended as replacement for DIN EN 14453 (2005-08).
| Fecha edición: |
2026-03-01
En Vigor
|
|---|---|
| Idiomas disponibles: | Alemán, Inglés |
| Resumen: | This document specifies: a) field of application; b) requirements for pipe interrupters with permanent atmospheric vent; c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20; d) test method and requirements for verifying these properties; e) marking and presentation; f) acoustics. This document specifies the characteristics of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20 that are suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 °C and for 1 h 90 °C. Backflow protection devices integrated in flushing valves are similar to DC and are not covered under this document. The requirements are stated in EN 12541. This document specifies: a) field of application; b) requirements for pipe interrupters with permanent atmospheric vent; c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20; d) test method and requirements for verifying these properties; e) marking and presentation; f) acoustics. This document specifies the characteristics of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20 that are suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 °C and for 1 h 90 °C. Backflow protection devices integrated in flushing valves are similar to DC and are not covered under this document. The requirements are stated in EN 12541. |
| Keywords: | Air inlet|Anti-siphonage systems|Backflow|Check valves|Chemical properties|Connecting dimensions|Definitions|Design|Designations|Dimensions|Draw-off taps|Drinking water control|Drinking water installations|Drinking water supply|Flow rates|Fluid equipment components|Hazards|Hygiene|Marking|Material properties|Materials|Mounting dimensions|Noise|Pipe interruptors|Pipeline installations|Pipes|Pipework systems|Pollution of drinking water|Potable water|Properties|Protection of water resources|Protective measures|Quality|Quality assurance|Reflux|Reflux control|Safeguarding systems|Safety devices|Safety measures|Safety valves|Security measures|Specification (approval)|Temperature|Testing|Tightness|Valves|Water|Water fittings|Water pollution|Water practice|Water purification|Water quality|Water supply|Water supply (buildings)|Water supply installations |
| ICS: | 13.060.20 - Agua potable, 23.060.50 - Válvulas de retención |
| CTN: |