DIN EN 16020:2011-10
Explosion diverters; German version EN 16020:2011
| Fecha edición: |
2011-10-01
En Vigor
|
|---|---|
| Idiomas disponibles: | Inglés, Alemán |
| Resumen: | An explosion diverter is used to divert explosions propagating through ducts. The device is used to prevent flame jet ignition and pressure piling in connected protected enclosures. It will reduce the risk of flame transmission. This document describes the basic design of a pipe-in-pipe diverter and specifies the testing requirements and the application of explosion diverters. It covers a test method for assessing the efficacy of explosion diverters, design rules for a type of pipe-in-pipe diverter, demands to venting device on the diverter, installation and maintenance requirements and marking. This document considers dust/air explosive atmospheres only. |
| Keywords: | CE marking|Definitions|Design|Explosion hazard|Explosion protection|Explosion-proof|Explosive|Flammable atmospheres|Marking|Pipelines|Protection devices|Safety engineering|Specification (approval)|Testing|User information |
| ICS: | 13.230 - Protección contra explosiones |
| CTN: | |
|
Equivalencia Internacional |
Idéntica EN 16020:2011 |
|
Reemplazo Normas |
Reemplaza a DIN EN 16020:2009-12 |