DIN EN 2665-004:2014-03
Aerospace series - Circuit breakers, three-pole, temperature compensated, rated currents 20 A to 50 A - Part 004: UNC thread terminals - Product standard; German and English version EN 2665-004:2013
| Fecha edición: |
2014-03-01
En Vigor
|
|---|---|
| Idiomas disponibles: | Alemán, Inglés |
| Resumen: | This European Standard specifies the characteristics of three-pole circuit breakers, temperature compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between -55 °C and 90 °C at an altitude of 15000 m max. These circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping They will continue to function up to the short-circuit current. |
| Keywords: | Aerospace transport|Air transport|Aircraft components|Circuit-breakers|Connections|Currents|Designations|Dimensions|Electrical engineering|Electrical properties and phenomena|Electrical protection equipment|Electrical systems|Environmental condition|Explosion-proof|Marking|Mass|Mechanical properties|Product standards|Properties|Pull operation|Push operation|Pushbuttons|Rated current|Space transport|Specification (approval)|Switches|Switchgear|Temperature|Temperature-compensated|Thread fasteners|Three-pole|Tri-pole circuit-breakers|UNC thread fasteners|Weights |
| ICS: | 49.060 - Equipos y sistemas eléctricos en aeronaves |
| CTN: | |
|
Equivalencia Internacional |
Idéntica EN 2665-004:2013 |
|
Reemplazo Normas |
Reemplaza a DIN EN 2665-004:1999-08 Reemplaza a DIN EN 2665-004:2013-10 |