DIN EN ISO 4126-5:2016-12
Safety devices for protection against excessive pressure - Part 5: Controlled safety pressure relief systems (CSPRS) (ISO 4126-5:2013 + Amd 1:2016); German version EN ISO 4126-5:2013 + A1:2016
| Fecha edición: |
2016-12-01
En Vigor
|
|---|---|
| Idiomas disponibles: | Inglés, Alemán |
| Resumen: | This amandment of this part of this International Standard specifies the requirements for Controlled Safety Pressure Relief Systems (CSPRS) irrespective of the fluid for which they are designed. It is applicable for main valves having a flow diameter of 4 mm and above which are for use at pressures of 0,1 bar gauge and above. No limitation is placed on temperature. This is a product standard and is not concerned with applications. |
| Keywords: | CE marking|Compactness|Controlled|Definitions|Design|Dimensioning|Dimensions|Excess pressures|Explosion protection|Flow behaviour|Fluid pressure|Hydraulic tests|Identification plates|Industrial fittings|Marking|Materials|Overpressure protection|Performance tests|Pneumatic tests|Pressure|Pressure control valves|Pressure overload|Pressure regulators|Pressure tests|Product standards|Safety device|Safety devices|Safety requirements|Safety shut-off valves|Safety valves|Size|Specification|Specification (approval)|Stop valves|Symbols|Testing|Units|Valves |
| ICS: | 13.240 - Protección contra el exceso de presión |
| CTN: | |
|
Equivalencia Internacional |
Idéntica EN ISO 4126-5:2013/A1:2016 Idéntica ISO 4126-5:2013/Amd 1:2016 |
|
Reemplazo Normas |
Reemplaza a DIN EN ISO 4126-5:2013-12 Reemplaza a DIN EN ISO 4126-5/A1:2016-03 |