-50% de descuento* Si compras la misma norma UNE en distintos idiomas. * Dto. sobre el pvp inferior. Ver condiciones

DIN ISO 16000-14:2012-03

Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry (ISO 16000-14:2009)

Fecha edición: 2012-03-01
En Vigor
Idiomas disponibles: Inglés, Alemán
Resumen: This part of DIN ISO 16000 describes the extraction, clean-up and analysis of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from indoor air samples. After sampling on a filter and a back-up vapour trap (see DIN ISO 16000-13) the filter and the back-up vapour trap are extracted. The clean-up and the separation into a PCB and a PCDD/PCDF fraction are performed by column chromatography. For the analysis high-resolution gas chromatography combined with high-resolution mass spectrometry (HRGC/HRMS) is employed. Losses during extraction and clean-up are detected and compensated by using isotopically-labelled surrogates as internal extraction standards for quantification, together with recovery standards that are added just before the HRGC/HRMS analysis. The method provides accurate quantitative data for tetra- through deca-PCBs and tetra- through octa-PCDDs/PCDFs. It is capable of detecting 0,2 pg/m3 or lower concentrations of most PCBs and PCDFs/PCDDs with air sampling volumes up to 360 m3 or more in special cases. However, it may not be possible to detect all analytes at 0,2 pg/m3 or lower, especially at lower sampling volumes. Precision under normal conditions can be expected to be ± 25 % or better and uncertainty ± 50 % or better. Sampling of PCBs, PCDDs/PCDFs is described in ISO 16000-13; it is part of the overall PCB/PCDD/PCDF measurement procedure. The sampling strategy to analyse PCBs, PCDDs/PCDFs and PAHs in indoor air is described in DIN ISO 16000-12.

Keywords: Air|Air pollution|Air quality|Analysis|Atmospheric pollutants|Chemical analysis and testing|Comparison measurement|Definitions|Determination|Determination of content|Determination procedures|Emission|Emission measurement|Gas chromatography|Impurities|Indoor climate|Indoors|Inner atmosphere|Mass spectrometry|Measurement|Measuring techniques|Metrology|Particulate matter measurement|PCB|PCDD|PCDF|Pollutant concentration|Pollutants|Pollution control|Pollution of the air|Polochlorinated dibenzo-p-dioxin|Polychlorinated|Polychlorinated biphenyls|Polychlorinated dibenzofuran|Prevention of pollution|Quality assurance|Sampling|Sampling methods|Testing|Volatile matter determination
ICS: 13.040.20 - Aire ambiente
CTN:

Equivalencia Internacional

Idéntica ISO 16000-14:2009

Reemplazo Normas

Reemplaza a DIN ISO 16000-14:2007-10