IEC 61076-3-117:2009
Connectors for electronic equipment - Product requirements - Part 3-117: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface - Variant 14 related to IEC 61076-3-106 - Push-pull coupling
| Fecha edición: |
2009-04-29
En Vigor
|
|---|---|
| Idiomas disponibles: | Inglés, Francés |
| Resumen: | IEC 61076-3-117:2009 covers rectangular protective housings with push-pull coupling for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-41, IEC 60603-7-5, IEC 60603-7-51, IEC 60603-7-7 and IEC 60603-7-71 to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments. Common mating configurations for all variants of the 8-way shielded and unshielded connectors are defined in IEC 60603-7. La CEI 61076-3-117:2009 couvre les boîtiers de protection rectangulaires avec type d'accouplement pousser-tirer pour amener les connecteurs existants à 8 voies blindés et non blindés, utilisant l'interface décrite dans la CEI 60603-7-2, la CEI 60603-7-3, la CEI 60603-7-4, la CEI 60603-7-41, la CEI 60603-7-5, la CEI 60603-7-51, la CEI 60603-7-7 et la CEI 60603-7-71 aux niveaux IP65 et IP67 conformément à la CEI 60529, utilisés dans les environnements industriels. Les configurations d'accouplement communes à toutes les variantes des connecteurs blindés et non blindés à 8 voies sont définies dans la CEI 60603-7. |
| ICS: | 31.220.10 - Dispositivos de bases y clavijas. Conectores |
| CTN: | TC 48/SC 48B - 1373 |
|
Reemplazo Normas |
Reemplaza a IEC PAS 61076-3-117:2006 |